Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Clin Exp Optom ; 106(2): 165-170, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36403253

RESUMO

CLINICAL RELEVANCE: Vision Bus Aotearoa is a fully equipped mobile eye health clinic designed to provide a novel platform for undergraduate optometry clinical training, community eye health research and deliver services to underserved communities. BACKGROUND: Aotearoa New Zealand has inequitable access to eye health care. Vision Bus Aotearoa aims to work in partnership with communities to provide comprehensive mobile primary eye health care services while training optometry students, and integrating community eye health research. METHODS: A description is provided of the governance model which has been involved throughout the project. RESULTS: The process of vehicle manufacture, clinical set-up, funding models and service delivery are described. The aims of the project are detailed in terms of optometry teaching, clinical services in partnership with communities, and research integration and implementation. CONCLUSION: Vision Bus Aotearoa represents a valuable opportunity to deliver mobile eye health care to historically underserved communities, enhance undergraduate optometry teaching and to provide a unique platform for community eye health research.


Assuntos
Atenção à Saúde , Optometria , Humanos , Optometria/educação , Educação em Saúde , Saúde Pública , Nova Zelândia
2.
Clin Exp Optom ; 106(2): 110-118, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36336833

RESUMO

Access to culturally safe health services is a basic human right, however through the lasting effects of colonisation, oppression, and systemic racism, the individual and community health of Indigenous peoples in Australia and Aotearoa New Zealand have been severely impacted. The Aboriginal and Torres Strait Islander Health and Cultural Safety Strategy of the Australian Health Practitioners Regulation Agency, and the Standards of Cultural Competence and Cultural Safety of the Optometrists and Dispensing Opticians Board of New Zealand, recognise the importance of access to safe health care for Aboriginal, Torres Strait Islander and Maori patients, which encompasses both clinical competency and cultural safety. Universities have an ongoing responsibility to ensure their learning and teaching activities result in graduates being able to provide culturally safe practice. This article highlights the emergence of culturally safe practices in the Australian and Aotearoa New Zealand optometry curricula over the last five years incorporating Indigenous ways of knowing, being and doing into the curricula, understanding the local Indigenous histories and contexts, the adoption of online cultural education modules, and clinical placement partnerships with local Indigenous communities. Whilst there is still much work to do to achieve the goal of graduating culturally safe optometrists, this paper focuses on features that enable or impede progress in the development of culturally safe practices within the optometry programmes to improve eye health equity for Indigenous recognise the diversity of Indigenous cultures across Australia and NZ.


Assuntos
Serviços de Saúde do Indígena , Optometria , Humanos , Austrália , Optometria/educação , Nova Zelândia , Atenção à Saúde , Competência Cultural/educação , Instituições Acadêmicas
3.
J. optom. (Internet) ; 14(3)July - September 2021. tab
Artigo em Inglês | IBECS | ID: ibc-209005

RESUMO

Purpose: Convergence insufficiency, the most common binocular vision anomaly, is characterised by a receded near point of convergence and an exophoria which is at least 4 prism dioptres (Δ) larger at near than at distance. However, the repeatability of standard heterophoria measures are poorly understood. This study assessed the ability of four common heterophoria tests to detect differences of 4Δ by evaluating the inter- and intra-examiner variability of the selected techniques. Methods: Distance and near horizontal heterophorias of 20 visually-normal adults were measured with the alternating prism cover test, von Graefe prism dissociation, Howell Card and Maddox Rod by two examiners at two separate visits using standardised instructions and techniques. We investigated inter- and intra-examiner variability using repeatability and reproducibility indices, as well as Bland-Altman analysis with acceptable limits of agreement defined as ±2Δ. Results: The Howell card test had the lowest intra-examiner variability at both distance and near, as well as the best 95% limits of agreement (±1.6Δ for distance and ±3.7Δ for near). Inter-examiner reproducibility results were similar, although at near the alternating prism cover test had better repeatability (1.1Δ, 95% confidence intervals −1.1Δ to 4.0Δ) than the Howell card (1.4Δ, 95% confidence intervals −1.9Δ to 5.9Δ). Conclusion: The low repeatability of many standard clinical heterophoria tests limits the ability to reliably detect a 4Δ difference. The Howell Card provided the most repeatable and reproducible results indicating that this technique should be used to detect small changes in heterophoria magnitude and direction. (AU)


Assuntos
Humanos , Acomodação Ocular , Estrabismo/diagnóstico , Testes Visuais , Visão Binocular , Reprodutibilidade dos Testes
5.
J Optom ; 14(3): 275-281, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32798131

RESUMO

PURPOSE: Convergence insufficiency, the most common binocular vision anomaly, is characterised by a receded near point of convergence and an exophoria which is at least 4 prism dioptres (Δ) larger at near than at distance. However, the repeatability of standard heterophoria measures are poorly understood. This study assessed the ability of four common heterophoria tests to detect differences of 4Δ by evaluating the inter- and intra-examiner variability of the selected techniques. METHODS: Distance and near horizontal heterophorias of 20 visually-normal adults were measured with the alternating prism cover test, von Graefe prism dissociation, Howell Card and Maddox Rod by two examiners at two separate visits using standardised instructions and techniques. We investigated inter- and intra-examiner variability using repeatability and reproducibility indices, as well as Bland-Altman analysis with acceptable limits of agreement defined as ±2Δ. RESULTS: The Howell card test had the lowest intra-examiner variability at both distance and near, as well as the best 95% limits of agreement (±1.6Δ for distance and ±3.7Δ for near). Inter-examiner reproducibility results were similar, although at near the alternating prism cover test had better repeatability (1.1Δ, 95% confidence intervals -1.1Δ to 4.0Δ) than the Howell card (1.4Δ, 95% confidence intervals -1.9Δ to 5.9Δ). CONCLUSION: The low repeatability of many standard clinical heterophoria tests limits the ability to reliably detect a 4Δ difference. The Howell Card provided the most repeatable and reproducible results indicating that this technique should be used to detect small changes in heterophoria magnitude and direction.


Assuntos
Estrabismo , Acomodação Ocular , Humanos , Reprodutibilidade dos Testes , Estrabismo/diagnóstico , Testes Visuais , Visão Binocular
6.
PLoS One ; 12(2): e0170839, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28152076

RESUMO

PURPOSE: Children may be tested with a variety of visual acuity (VA) charts during their ophthalmic care and differences between charts can complicate the interpretation of VA measurements. This study compared VA measurements across four pediatric charts with Sloan letters and identified chart design features that contributed to inter-chart differences in VA. METHODS: VA was determined for right eyes of 25 adults and 17 children (4-9 years of age) using Crowded Kay Pictures, Crowded linear Lea Symbols, Crowded Keeler logMAR, Crowded HOTV and Early Treatment of Diabetic Retinopathy Study (ETDRS) charts in focused and defocused (+1.00 DS optical blur) conditions. In a separate group of 25 adults, we compared the VA from individual Kay Picture optotypes with uncrowded Landolt C VA measurements. RESULTS: Crowded Kay Pictures generated significantly better VA measurements than all other charts in both adults and children (p < 0.001; 0.15 to 0.30 logMAR). No significant differences were found between other charts in adult participants; children achieved significantly poorer VA measurements on the ETDRS chart compared with pediatric acuity tests. All Kay Pictures optotypes produced better VA (p < 0.001), varying from -0.38 ± 0.13 logMAR (apple) to -0.57 ± 0.10 logMAR (duck), than the reference Landolt C task (mean VA -0.19 ± 0.08 logMAR). CONCLUSION: Kay Pictures over-estimated VA in all participants. Variability between Kay Pictures optotypes suggests that shape cues aid in optotype determination. Other pediatric charts offer more comparable VA measures and should be used for children likely to progress to letter charts.


Assuntos
Testes Visuais/métodos , Acuidade Visual , Adolescente , Adulto , Fatores Etários , Criança , Pré-Escolar , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Transtornos da Visão/diagnóstico , Adulto Jovem
7.
Ophthalmic Physiol Opt ; 33(5): 563-72, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23668224

RESUMO

PURPOSE: In children, time spent outdoors has a protective effect against myopia development. In animal models, bright light reduces the development of experimental myopia. This study investigates how an increase in daily light exposure, presented either continuously during the day or periodically at different times of day, influences the development of experimental myopia in the chick. METHODS: Myopia was induced in Cobb Chicks (Gallus domesticus) by monocular deprivation (MD) of form vision with a translucent diffuser for 3 days (from 4 days of age) under a 12:12 light: dark cycle. MD control chicks were exposed to constant 300 lux (n = 11) during the light period. MD treatment groups received either constant 2000 lux (n = 11) during the light period or 300 lux for 10 h with a 2 h period of bright light (10 000 lux), either in the morning (n = 10), midday (n = 10) or evening (n = 10), giving the same total daily light exposure as the 2000 lux group. After 3 days of MD, refractive status, corneal curvature and axial eye dimensions were measured for all eyes under anaesthesia. RESULTS: Myopia in the constant 2000 lux group (-4.94 ± 1.21 D) was significantly less than in the 300 lux control group (-9.73 ± 0.96 D; p = 0.022). However, compared to the 300 lux control group, 2 h periods of 10 000 lux did not produce significant effects on refraction when presented either in the morning (-9.98 ± 0.85; p = 1.00), midday (-8.00 ± 1.26; p = 0.80), or evening (-13.14 ± 1.16 D; p = 0.20), although significantly less myopia was induced in the midday group compared to the evening group (p = 0.018). Orthogonal regression showed that myopia development was matched by changes in vitreous chamber depth (R(2)  = 0.69; p < 0.0001). CONCLUSIONS: In chicks, an increase in daily light exposure continuously during the day is more effective at inhibiting myopia than adding an equivalent dose within a 2 h period of bright light. A weak time-of-day effect also appears to be present in the response to bright light exposure. Our results suggest that future light-based myopia therapies in humans may be more effective if light levels are increased over the whole day, rather than through short periods of bright light exposure.


Assuntos
Exposição Ambiental , Luz , Miopia/prevenção & controle , Fotoperíodo , Refração Ocular/efeitos da radiação , Animais , Galinhas , Modelos Animais de Doenças , Análise Multivariada , Miopia/etiologia , Miopia/patologia , Corpo Vítreo/patologia
8.
Invest Ophthalmol Vis Sci ; 49(11): 4784-9, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18566472

RESUMO

PURPOSE: To determine whether the distribution of naturally occurring myopia in Labrador Retrievers has a genetic component. METHODS: Pedigree records of a large canine family were analyzed. Pure Labrador Retrievers, 1 to 8 years of age, free of ocular disease, and available for testing were studied. Refractive error was measured by cycloplegic retinoscopy in both eyes. The family included mating loops, and so an expectation maximization (EM) algorithm (multivar program, MORGAN software; University of Washington, Seattle) was used to calculate log likelihoods of refractive error with environmental and additive genetic models. The fixed effects of coat color, sex, and litter size were also tested. RESULTS: In our sample of 116 dogs from this one family, the average spherical equivalent refraction (SER) was -0.41 D (range, -5.38 to +1.65 D, mean of both eyes, n = 116): 31% were myopic (SER or= +1.00 D). The significance of fixed and genetic effects was tested by comparing the full model (including genetic and all fixed effects) to models with one effect removed. Litter size and additive genetic effects were significant (P = 0.0013 and P = 0.000093, respectively), whereas sex and coat color were not. The overall variance in SER was accounted for approximately equally by additive genetic variance and residual/environmental variance. Narrow sense heritability of SER was 0.506. CONCLUSIONS: The distribution of refractive error within this family of Labrador Retrievers had a significant genetic component, but was also influenced by other factors (litter size, and undefined residual/environmental effects). The dog represents a unique model for the study of naturally occurring, heritable, high-prevalence, low-degree myopia.


Assuntos
Doenças do Cão/genética , Predisposição Genética para Doença , Miopia/congênito , Linhagem , Refração Ocular/fisiologia , Animais , Doenças do Cão/fisiopatologia , Cães , Feminino , Masculino , Miopia/genética , Miopia/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...